Configure SDI-12 Readings

The SDI-12 interface is a low data rate protocol designed for agricultural and scientific sensors (SDI-12 Website).

A soil moisture probe will often have multiple sensors along its length. Each sensor can have an address between 0 and 9 (inclusive), and allows for up to 10 different 'measurements'. Each of these measurements can actually return a number of different values (up to 15). For example, a soil moisture probe may have a soil moisture and soil temperature measurements, and each of these will return a number of values, each being taken at a certain point along the probe.

Configure SDI-12 Readings

Configure Task

Configure SDI-12 Action 1 or 2 as an action for a task. The below task is for an SDI-12 reading logged + uploaded hourly.

Configure Vboost Voltage Level

While the SDI-12 bus operates at 5V, most SDI-12 probes require 12V to power the sensors. 

We need to tell the Hawk to output 12V via the Ag-Tech1 boost output.

Configure SDI-Reading

We specify

SDI 12 Address
Address of the probe to read
Log Identification/Use Old Data Field

SDI-12 data is sent in the following fields. Field 34 is new to the Hawk. 

If we only have 1 SDI-12 measurement we are taking, from 1 address, it is not necessary to identify this in the payload. So to save data we can select Log Identification as No

In general the default Log Identification = No and Use old Data Field = No should be used for most applications.

FID = 4: SDI-12 Device Identification

Length = N + 1

Offset

Data Type

Length

Description

Unit

0

BYTE

1

Device Address

(SDI12 single char address)

 

1

BYTE

N

SDI12 Identification string

(typically 30 ASCII characters)

 

 

FID = 5: SDI-12 Measurement

Length = 1 + N*4

The SDI12 spec allows for a device to support 10 different types of measurements (0-9).

Offset

Data Type

Length

Description

Unit

0

BYTE

1

SDI12 Measurement Type (0-9)

 

1 + N*4

INT32

4

Measurement (scaled by 1000)

<n data values follow>

Scaled by 1000

Eg milli-degrees centigrade

FID = 34: SDI-12 Measurement 2

Length =3 + N * X

This field replaces FID 4 on newer devices.

The SDI12 spec allows for a device to support 10 different types of measurements (0-9).

 

Offset

Data Type

Length

Description

Unit

0

BYTE

1

Device Address

(SDI12 single char address)

 

1

BYTE

1

SDI12 Measurement Type (0-9)

 

2

BYTE

1

SDI12 Data Format

0x00 = Scaled by 1000, stored in INT32

 

Other values are reserved.

3

Dependant on format

N * X

N measurements of size X, specified by the format.

 

Log IdentificationUse Old Data FieldFields Sent
NoNoFID 34
NoYesFID 5
YesNoFID 4 + FID 34
YesYesFID 4 + FID 5
Power on Delay
Most sensors require some time after power is applied to 'warm-up' or settle down before the reading is taken.
Run Measurement N
Select from the dropdowns which measurements we would like to run

Example

  • Sensor Address 0
  • Use the new data field, with no ID field
  • Power on delay 15 seconds
  • Measurements 1, 4 and 7