Support Home Portal Log in
Open navigation

Oyster Edge - Default I/O Mappings

Here are the Default I/O Mappings for Digital Matter's Oyster Edge tracker. You can change some of these mappings on OEM server - we do not recommend changing these unless you know what you are doing.
These mapping can be very handy to identify and debug issues. 

For example, if the device is connecting to the server/platform intermittently, this maybe an issue with coverage which can be confirmed by analyzing/plotting Analogue 4 (Cellular Signal Strength).

Analogue Mapping
Description
1
Battery Voltage
3
Temperature
4
Cellular Signal Strength
5
Loaded Voltage


Digital  Mapping
Description
0
Ignition
1
'Battery Good' Flag
1 = Good
2 = Low
2
'Battery Critical' Flag
1 = Critical

See Battery Level Monitoring [Oyster Edge] for information on the battery flags.

All DM devices have 'status flags'. The status flags are sent in Field 2 to 3rd party servers. However in Telematics Guru, they are remapped to the following Digital Inputs. 

Digital  Mapping
Description
24Trip State
1 = in trip
25 Battery Good
1 = good
0 = low
29Battery Critical
1 = critical


Additionally, in TG, information about the resolved location is mapped to analogues for ease of viewing.