Here are the Default I/O Mappings for Digital Matter's G70 tracker. You can change some of these mappings on OEM server - we do not recommend changing these unless you know what you are doing. Additionally, some firmware features provide their 'result' as a Digital Input flag - i.e. Idling flag. It is important when configuring these inputs to avoid clashing with inputs already mapped.

These mapping can be very handy to identify and debug issues. 

For example, if the device is connecting to the server/platform intermittently, this maybe an issue with coverage which can be confirmed by analyzing/plotting Analogue 4 (Cellular Signal Strength). Another example of an issue that we see often is trips not being detected/initialized properly - this maybe an issue with the ignition wiring - by looking at Digital 0 would help troubleshoot such issues.

Analogue Mappings

Analogue Mapping
Description
1
Battery Voltage
2
External Voltage
3
Temperature
4
Cellular Signal Strength
5
Analogue Input


Digital Mappings

Digital  Mapping
Description
0
Ignition
1
Input 1
2
Input 2
3
Input 3
5
GPS Interference
6GPS Jamming


Status Flags

All DM devices have 'status flags'. The status flags are sent in Field 2 to 3rd party servers. However in Telematics Guru, they are remapped to the following Digital Inputs.

Digital  Mapping
Description
24Trip State
25Internal Battery 'Good'
26External Battery
'Good'
27Connected to Server
28Charging